Sustainability / Glulam Resource Centre


The more we rely on and use sustainable managed plantation timber, the healthier and "greener" our planet will become.

Steel & concrete create co²; timber consumes it. We should always be looking for a clean and green solution when building, timber is that solution.


Durabeam® & Unilam® - A "Greener" Solution


Durabeam® is made only from locally sourced, sustainably managed Australian White Cypress and is a patent product. Laminated beam products may contain timbers that are sourced from international rainforests be sure to insist that the timbers used in your specified beams are not rainforest species such as Alaskan Yellow cedar or Yellow cypress!

Durabeam® and Unilam® products help protect the environment. The growing of managed plantation timbers for manufacturing, whilst young absorb co² reducing gas emissions to the atmosphere. When harvested and processed, timber uses up very little energy compared to steel, that consumes up to 24 times and aluminium consumes a massive 126 times more energy per tonne. Durabeam® and Unilam® are an excellent alternative to steel, not only as a renewable resource but by using solar energy to aid in the growing and manufacturing of these timber products.

These certificates represent our commitment to complying with chain of custody verification.



Australian
White Cypress

PDF download (116kb)


Australian
White Cypress

PDF download (152kb)


Victorian Ash / Tasmanian Oak

Pdf download (228kb)


Radiata
Pine

Pdf download (1004kb)

 

 


ARCHITECT ENGINEERING DESIGN INFORMATION

Specifying Glulam

EXTERIOR APPLICATION;

LOSP Treatment to H3 minimum (External moderate risk)

INTERIOR APPLICATION;

LOSP Treatment to H2 minimum (Internal high risk - termite resistant)
EACH BEAM stamped according to Engineering properties and as per Australian Standards



APPEARANCE GRADES

‘A’ Grade - Beams: Sanded, voids filled, with a premium clear finish
‘B’ Grade - Beams: Dressed, suitable for painting or framing applications



SERVICE GRADES (FOR EXTERNAL USE)

SERVICE CLASS 1 - Environmental conditions with EMC not to exceed 12% in service
SERVICE CLASS 2 - Environmental conditions with EMC up to 20% in service
SERVICE CLASS 3 - EMC will exceed 20% i.e. Fully exposed structures - bridges / pergolas. etc



GLULAM (GL GRADES)

New Engineering grades have been developed Nationally to define structural properties from the old "F" ratings used for solid timber and Glulam. The moduIus of EIasticity (E) is the structural value that governs deflection and design generally, ie. GL18 has an E value of 18.500 Mpa (F27)



PRECAMBER

Australian Standard camber is 600mm radius to compensate The influence of long beam sag under permanent dead load.

 

Design Properties Radiata Pine GL10 Cypres Pine GL10 Radiata Pine GL13 Slash Pine GL17 Vic Ash GL17 Tas Oak GL18
Bending ƒ' b (Note 1) 22 MPa 22 MPa 33 MPa 42 MPa 42 MPa 50 MPa
Tension ƒ' t 11 MPa 11 MPa 16 MPa 21 MPa 21 MPa 25 MPa
Shear ƒ' s 3.7 MPa 3.7 MPa 3.7 MPa 3.7 MPa 3.7 MPa 5.0 MPa
Compression ƒ' c 26 MPa 26 MPa 33 MPa 35 MPa 35 MPa 50 MPa
E 10000 10000 13300 16700 16700 18500
G 670 670 900 1110 1110 1230
Strength Group SD6 SD6 SD6 SD5 SD4 SD4
Joist Group JD4 JD3 JD4 JD3 JD3 JD3
Density 550 700 550 650 650 650
Durability Rating 4 1 4 4 4 4



GLULAM DESIGN PROPERTIES – Limit state design properties to AS.1720.1-1997
Notes:
1. Tension parallel to grain.
2. Compression parallel to grain.
3. Short duration modulus of elasticity parallel to grain.

QUALITY ASSURANCE

All beams manufactured for structural applications must be third party accredited, All TES Products supplied are produced in accordance with AS NZS1328.2, 1998 of the Glued Laminated Timber Association of Australia, from accredited members or products under accreditation.

HANDLING AND STORAGE

All appearance grade Laminated Timber products will be supplied with plastic waterproof wrapping. The product should be kept dry off ground and handled with web slings only. It is recommended that beams or posts exposed to short or long term weathering should be coated with a ‘Cutek’ oil based product which, with successive coating and maintenance will ensure long life to the components and structure.


Burning Evidence

The Durabeam and Unilam series of glue laminated beams are difficult to ignite. Glulam burns very slowly and resists heat penetration by the formation of a layer of charcoal. This char forms a layer of insulation which keeps the encased limber cool, even though the fire's temperature may be over 1000ºC. As a result, a large beam, which has been designed to support its design load in even the severest of fires, will maintain its strength. Also, glulam does not expand or deform enough to push out supporting walls. Metals on the other hand soften very quickly, lose all effective strength and then expand sufficiently to push out supporting walls before collapsing completely.

The Printing Factory


A GUIDE TO FIRE PERFORMANCE

While wood will burn the larger sizes of wood products, such as glued laminated timber, burn more slowly than smaller size dimension lumber and this is taken into account in design.

HEAVY TIMBER CONSTRUCTION

Heavy timber construction has long been recognized by the model building codes as fire resistant. To receive building code acceptance as "heavy timber," limitations are placed upon size and thickness or composition of all load carrying wood members. Heavy timber also avoids
concealed spaces under floors and roofs and requires the use of approved fastenings, construction details and adhesives.

The performance of heavy timber construction under fire conditions is markedly superior to most unprotected non-combustible structures. Fire fighting is simpler and safer due to elimination of concealed spaces and the inherent structural integrity of large glued laminated timbers.

FIRE RESISTANCE

Fire resistance rating is the amount of time a member can support its load without collapsing or spreading fire, either directly or indirectly through heat transfer. A one hour rating, for example, means that an assembly should be capable of supporting its full load without collapsing for at least one full hour after the fire starts.

Fire tests sponsored jointly by AFPA and AITC have Ied to the development of a fire design methodology which allows the designer to calculate a specific fire rating for a glulam member. This information is available from the American Institute of Timber Construction. Please contact your AITC laminated timber supplier or AITC and ask for "Glulam Performance Under Fire Exposure," and AITC Technical Note # 7 "calculation of Fire Resistance of Glued Laminated Timbers."

MATERIALS COMPARISON

Most are surprised when Heavy Timber construction is compared with other structural building materials' fire resistant properties. Unprotected metals lose their strength quickly and collapse suddenly under extreme heat. Steel weakens dramatically as its temperature climbs above 450 degrees Fahrenheit, retaining only 1O% of its strength at about 1380ºF (average building fire temperatures range from 1290ºF to 165OºF). Wood retains a significantly higher percentage of its original strength for a longer period of time, losing strength only as material is lost through surface charring.

Typical glulam beam following test. Note that the outer surface of beam has charred, while inner areas remain unburned. The charred outer material acts as an insulator during fire, reducing the rate at which the inner material will burn.

The Mandalay Motel The Printing Factory
These structures were completely sandblasted, restored and back in service after a high intensity fire.


The fact that large wood structural members provide a substantial degree of fire endurance was recognized as early as 1800 when heavy timber framing assumed importance in the design of factory buildings. When a group of cotton and woolen mill owners organized in 1835 for mutual protection of their property from damage by fire, this system of construction increased in prominence and became identified as "mill construction." The outgrowth of this organization was the formation of what is now known as the Associated Factory Mutual Fire Insurance Companies.

A long history of over 150 years of excellent performance in numerous severe ires has established the superior fire endurance of heavy timber framing. The term, "mill construction," originally applied to this type of building, has gradually disappeared in favor of the more definite term, "heavy timber construction," as now recognized in major building codes throughout the country.

With the advent of modern structural glues and gluing techniques in recent years, the engineered timber fabricating industry has greatly expanded the scope of architectural application for "heavy timber construction."

Originally used for factories and warehouses, it has also become a preferred method of construction for churches, schools, and other places of assembly. There are many outstanding examples of this new method of timber framing which utilizes glued-laminated structural members in a variety of sizes and shapes to fit a broad range of architectural forms.

For many years, heavy timber framing has been considered a preferred risk by fire insurance rating bureaus and a superior type by fire protection authorities. The records include numerous examples in which buildings of heavy timber construction have been restored to use at minimum expense after severe fire exposure. In many cases, removal or char by sandblasting or other means was the only repair work needed.

The char which forms on timber during a fire is an effective insulator which protects the inner section of timber from the effects of heat. At a distance of 20mm from the edge of the char, the internal temperature of the wood will only be about 80ºC. At this temperature, the beam will retain 80% of its tension and compression strength, and 95% of its stiffness (modulus of elasticity). This contrasts with other structural materials such as unprotected steel I-beams. Comparative fire tests of timber and steel showed that a steel I-beam deflected 900mm after 30 minutes' exposure to a standard fire, while a glue laminated timber beam of the same load-bearing capacity deflected only 60mm.

Under fire conditions, charring continues at a rate proportional to the timber's density. Assuming a density of 500kg/m3 for radiate pine at 12% moisture content, the charring rate of a 'Glulam' beam is given by the following formula:










The thermal expansion of timber is minimal and in practice is usually overshadowed by shrinkage due to loss of moisture. Timber is therefore unlikely to cause structural damage through thermal expansion.

The South Australian Metropolitan Fire Servlce has testified to the excellent fire performance of timber in the following statement:

"Most firefighters, especially the older ones familiar with timber construction, would prefer to enter a timber frame building to fight a fire within it, than a similar building constructed in unprotected steel, because the collapse of a timber structure is apparently more predictable than a steel one. We believe that a fire engineered approach to the incorporation of timber within building construction is feasible arid should be pursued".